• Low smoke halogen-free flame retardant aluminum alloy cable AAAC 4*240mm2+1*120mm2 0.6/1KV
  • Low smoke halogen-free flame retardant aluminum alloy cable AAAC 4*240mm2+1*120mm2 0.6/1KV
  • Low smoke halogen-free flame retardant aluminum alloy cable AAAC 4*240mm2+1*120mm2 0.6/1KV
  • Low smoke halogen-free flame retardant aluminum alloy cable AAAC 4*240mm2+1*120mm2 0.6/1KV
  • Low smoke halogen-free flame retardant aluminum alloy cable AAAC 4*240mm2+1*120mm2 0.6/1KV
  • Low smoke halogen-free flame retardant aluminum alloy cable AAAC 4*240mm2+1*120mm2 0.6/1KV
  • Low smoke halogen-free flame retardant aluminum alloy cable AAAC 4*240mm2+1*120mm2 0.6/1KV
  • Low smoke halogen-free flame retardant aluminum alloy cable AAAC 4*240mm2+1*120mm2 0.6/1KV
  • Low smoke halogen-free flame retardant aluminum alloy cable AAAC 4*240mm2+1*120mm2 0.6/1KV
  • Low smoke halogen-free flame retardant aluminum alloy cable AAAC 4*240mm2+1*120mm2 0.6/1KV
  • Low smoke halogen-free flame retardant aluminum alloy cable AAAC 4*240mm2+1*120mm2 0.6/1KV
  • Low smoke halogen-free flame retardant aluminum alloy cable AAAC 4*240mm2+1*120mm2 0.6/1KV

Low smoke halogen-free flame retardant aluminum alloy cable AAAC 4*240mm2+1*120mm2 0.6/1KV

MOQ
10KM
Size
10~400mm2
Custom
Customizable
Standard
Customer area standard
  • Low smoke halogen-free flame retardant aluminum alloy cable AAAC 4*240mm2+1*120mm2 0.6/1KV
  • Low smoke halogen-free flame retardant aluminum alloy cable AAAC 4*240mm2+1*120mm2 0.6/1KV
  • Low smoke halogen-free flame retardant aluminum alloy cable AAAC 4*240mm2+1*120mm2 0.6/1KV
  • Low smoke halogen-free flame retardant aluminum alloy cable AAAC 4*240mm2+1*120mm2 0.6/1KV
  • Low smoke halogen-free flame retardant aluminum alloy cable AAAC 4*240mm2+1*120mm2 0.6/1KV
  • Low smoke halogen-free flame retardant aluminum alloy cable AAAC 4*240mm2+1*120mm2 0.6/1KV
Desciption
Application:
Low-smoke halogen-free flame retardant aluminum alloy non-armored cables are designed for general purpose residential, commercial and industrial buildings. In the absence of armoured mechanical protection, unarmoured cables have a very wide range of applications. They can be used to feed lighting and other electrical equipment in non-combustible buildings, such as office buildings, hotels, shopping centers and factories.
1. Suitable for 600V~35kV voltage level; Suitable for dry or wet places at 90℃;
2. Can be installed indoors and outdoors, can be installed vertically, can also be supported or laid along the wall, the bending radius is at least 7 times the outer diameter, and can also be bent 360°;
3. Suitable for civil, commercial, industrial, large venues, entertainment venues, mines, subways and various levels of dangerous areas.

CONSTRUCTION:
Conductor: All Aluminum Alloy Conductor(AAAC)
Insulation: XLPE
Sheath: PE
Rated operating voltage: 0.6/1kV、3.6/6kV、6/10kV、8.7/15kV、12/20kV、 18/30kV、21/35kV、26/35kV
Working environment: The minimum operating environment temperature is -40 degrees Celsius, the maximum rated temperature for long-term operation of the low-smoke halogen-free cable conductor is 90 degrees Celsius, and it is resistant to solar aging.


Standard:
  • IEC60502 latest version of the standard
  • GB-T(China)
  • GB   (China)